[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"cve-CVE-2020-28393":3},{"id":4,"cve_id":5,"euvd_id":6,"summary":7,"published":8,"cvss_data":9,"is_remote":25,"cwes":26,"cpes":28,"technologies":51,"references":74,"score":77,"epss_score":78,"epss_percentile":79,"is_kev":80,"cisa_kev_date_added":81,"cisa_kev_due_date":81,"cisa_ssvc":82,"attack_mappings":88,"exploits":95},262666,"CVE-2020-28393","EUVD-2020-20852","An unauthenticated remote attacker could create a permanent denial-of-service condition by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device on the SCALANCE XM-400, XR-500 (All versions prior to v6.4).","2021-05-12T14:15:00Z",{"cvss_v2.0":10,"cvss_v3.1":18},{"version":11,"baseScore":12,"accessVector":13,"vectorString":14,"authentication":15,"integrityImpact":15,"accessComplexity":16,"availabilityImpact":17,"confidentialityImpact":15},"2.0",7.1,"NETWORK","AV:N\u002FAC:M\u002FAu:N\u002FC:N\u002FI:N\u002FA:C","NONE","MEDIUM","COMPLETE",{"scope":19,"version":20,"baseScore":21,"attackVector":13,"baseSeverity":22,"vectorString":23,"integrityImpact":15,"userInteraction":15,"attackComplexity":24,"availabilityImpact":22,"privilegesRequired":15,"confidentialityImpact":15},"UNCHANGED","3.1",7.5,"HIGH","CVSS:3.1\u002FAV:N\u002FAC:L\u002FPR:N\u002FUI:N\u002FS:U\u002FC:N\u002FI:N\u002FA:H","LOW",true,[27],"CWE-682",[29,30,31,32,33,34,35,36,37,38,39,40,41,42,43,44,45,46,47,48,49,50],"cpe:2.3:o:siemens:scalance_xm416-4c_l3_firmware:*:*:*:*:*:*:*:*","cpe:2.3:h:siemens:scalance_xr528:-:*:*:*:*:*:*:*","cpe:2.3:o:siemens:scalance_xr528_firmware:*:*:*:*:*:*:*:*","cpe:2.3:o:siemens:scalance_xr552_firmware:*:*:*:*:*:*:*:*","cpe:2.3:o:siemens:scalance_xr524_firmware:*:*:*:*:*:*:*:*","cpe:2.3:h:siemens:scalance_xm408-4c:-:*:*:*:*:*:*:*","cpe:2.3:o:siemens:scalance_xm-400_firmware:*:*:*:*:*:*:*:*","cpe:2.3:o:siemens:scalance_xm408-4c_l3_firmware:*:*:*:*:*:*:*:*","cpe:2.3:o:siemens:scalance_xm408-8c_firmware:*:*:*:*:*:*:*:*","cpe:2.3:o:siemens:scalance_xm408-4c_firmware:*:*:*:*:*:*:*:*","cpe:2.3:h:siemens:scalance_xr526:-:*:*:*:*:*:*:*","cpe:2.3:h:siemens:scalance_xm408-8c:-:*:*:*:*:*:*:*","cpe:2.3:o:siemens:scalance_xr526_firmware:*:*:*:*:*:*:*:*","cpe:2.3:o:siemens:scalance_xm408-8c_l3_firmware:*:*:*:*:*:*:*:*","cpe:2.3:h:siemens:scalance_xm408-8c_l3:-:*:*:*:*:*:*:*","cpe:2.3:h:siemens:scalance_xm416-4c_l3:-:*:*:*:*:*:*:*","cpe:2.3:h:siemens:scalance_xm408-4c_l3:-:*:*:*:*:*:*:*","cpe:2.3:h:siemens:scalance_xr552:-:*:*:*:*:*:*:*","cpe:2.3:h:siemens:scalance_xm416-4c:-:*:*:*:*:*:*:*","cpe:2.3:h:siemens:scalance_xm-400:-:*:*:*:*:*:*:*","cpe:2.3:o:siemens:scalance_xm416-4c_firmware:*:*:*:*:*:*:*:*","cpe:2.3:h:siemens:scalance_xr524:-:*:*:*:*:*:*:*",[52,53,54,55,56,57,58,59,60,61,62,63,64,65,66,67,68,69,70,71,72,73],"Siemens Scalance Xm408-8C L3","Siemens Scalance Xr528","Siemens Scalance Xm-400","Siemens Scalance Xm408-8C L3 Firmware","Siemens Scalance Xm416-4C","Siemens Scalance Xr526","Siemens Scalance Xm416-4C Firmware","Siemens Scalance Xm408-4C L3 Firmware","Siemens Scalance Xm408-8C Firmware","Siemens Scalance Xr528 Firmware","Siemens Scalance Xr552","Siemens Scalance Xm-400 Firmware","Siemens Scalance Xm408-8C","Siemens Scalance Xr524 Firmware","Siemens Scalance Xm408-4C Firmware","Siemens Scalance Xm408-4C L3","Siemens Scalance Xr526 Firmware","Siemens Scalance Xr552 Firmware","Siemens Scalance Xm416-4C L3 Firmware","Siemens Scalance Xm416-4C L3","Siemens Scalance Xm408-4C","Siemens Scalance Xr524",[75,76],"https:\u002F\u002Fcert-portal.siemens.com\u002Fproductcert\u002Fpdf\u002Fssa-116379.pdf","https:\u002F\u002Fus-cert.cisa.gov\u002Fics\u002Fadvisories\u002Ficsa-21-131-10",0.57,0.01629,0.76027,false,null,{"timestamp":81,"automatable":83,"tech_impact":84,"exploitation":85,"cisa_decision":86,"cisa_remediation_timeline":87},"no","partial","none",{},"FSU",[89],{"name":90,"source":91,"tactics":92,"technique_id":94},"Exploit Public-Facing Application","attack_vector",[93],"initial-access","T1190",[]]